I/O list
Points, signal types, and field devices. We size the I/O with spare capacity and pick the modules.
Engineered panels
When you need the panel designed as well as built, we produce schematics, panel layout, BOM, and SCCR calculation in 2D AutoCAD for your approval, then build and test it.
Inputs
Most engineered panels start from less than a full spec. These are enough to begin.
Points, signal types, and field devices. We size the I/O with spare capacity and pick the modules.
Motors, heaters, and other loads with ratings, so we can size branch protection, contactors, drives, and the main disconnect.
A description of what the machine or system does, so control circuits and safety functions are drawn correctly.
A hand sketch or an old drawing with changes is a perfectly good starting point.
The site’s electrical specification, preferred brands, and labeling rules.
Supply voltage, available fault current, ambient temperature, and environment for the enclosure rating and cooling.
Deliverables
Drawn in 2D AutoCAD. Conveyor companies that sell the panel under their name can have their own title block. You approve the set before material is ordered.
Power distribution, control circuits, PLC I/O, safety circuits, and network, with cross-references and wire numbers.
Backplate and door layouts at scale, with duct, terminal strips, clearances, and enclosure cutouts.
Every part with manufacturer and part number, including terminals, duct, labels, and hardware.
Per UL 508A Supplement SB, with the limiting component identified.
Heat dissipation estimate and the cooling choice that follows from it: vents, fans, or an air conditioner.
Brand-flexible BOMs
Many warehouses and plants standardize on Allen-Bradley. Others leave it open, or the AB part is on a long lead time. We price the BOM so you can choose line by line.
For key items such as the PLC, I/O, power supplies, disconnect, motor protection, and terminals, the BOM can show an Allen-Bradley option next to an alternate.
Each alternate notes what changes with it: footprint, SCCR, wiring, lead time, and any configuration or software impact.
Keep AB where the site standard or the PLC platform requires it, and use alternates elsewhere to cut cost or lead time.
Changing a breaker, fuse holder, or motor starter can change the panel SCCR. Every alternate is checked against the SCCR calculation before it’s offered.
Safety relays, contactors used in safety circuits, and E-stop devices are only swapped when the alternate has the safety data needed for the PL or SIL calculation.
The approved choice is the BOM revision we build to. No partial updates.
Design rules
Spare I/O, spare terminals, and space on the backplate for changes that always come late.
Field device power fused separately from the PLC, so a shorted sensor doesn’t drop the controller.
High-voltage and low-voltage sections separated, drives placed for airflow, and terminals reachable without removing components.
Consistent device tags and cross-references, so an electrician can trace a circuit without calling anyone.
Next step
Send the I/O list, load list, or a sketch. We’ll come back with questions and a price for drawings plus build.
Mon–Fri, 9:00 AM – 4:00 PM ET · we reply within one business day